Dapeng laser specializing in R&D, manufacturing fiber laser marking machine, industrial laser welding machines and laser sheet cutting machine, we also provides Laser sources and spare parts to the laser machine manufacturers in China and surrounding countries.
Availability: | |
---|---|
Quantity: | |
HL-12000
The HL-12000 High-Power Water Cooling System is designed for optimal cooling of 12000W fiber laser cutting machines, ensuring efficient operation and extending the lifespan of the equipment. Here are the specifications and key features for the HL-12000-QG2/2 model:
Model: HL-12000-QG2/2
Power Supply: 380V, 50Hz
Power Consumption: 14.0 kW
Coolant: R410A
Fluorine Injection: 2.70 kg (amount of refrigerant used)
Lift (Head Pressure): 68.0 meters (capability to pump water to this height)
Flow Rate: 8 m³/h (water flow rate ensuring effective cooling)
Weight: 220 kg (overall weight of the chiller unit)
Equipment Size: 1100 mm * 810 mm * 1880 mm (dimensions of the chiller unit)
Water Volume: 150 liters (capacity of the water tank within the chiller)
High Cooling Capacity: Specifically designed for 12000W fiber laser cutting machines, the HL-12000 provides robust cooling to handle the high thermal load.
Efficient Refrigerant: Uses R410A refrigerant, known for its high efficiency and reduced environmental impact compared to older refrigerants.
Powerful Performance: The chiller’s high power consumption (14.0 kW) indicates its capability to provide effective cooling for high-power laser systems.
Durable Construction: Built to withstand the demands of industrial environments, ensuring long-term reliability and minimal maintenance.
Compact Design: Despite its powerful cooling capabilities, the chiller is designed to fit within a compact footprint, making it suitable for various industrial setups.
Fiber Laser Cutting Machines: Ideal for cooling 12000W fiber laser systems used in industries such as metal fabrication, aerospace, automotive, and other sectors requiring advanced laser cutting technology.
Heavy-Duty Industrial Use: Suitable for environments where continuous, high-performance cooling is required to maintain operational efficiency and equipment longevity.
The HL-12000 ensures that your high-power fiber laser cutting machine operates at optimal temperatures, reducing the risk of overheating and enhancing overall performance. If you need more information or have specific questions about the HL-12000 chiller, feel free to ask!
HL Series Fiber Laser Chillers:
No. | Equipment Model | Power Supply | Power (kW) | Coolants | Fluorine Injection (kg) | Lift (m) | Flow Rate (m³/h) | Weight (kg) | Equipment Size (mm) | Water Volume (L) |
---|---|---|---|---|---|---|---|---|---|---|
1 | HL-1000-QG2/2 | 220V, 50Hz | 1.7 | R410A | 0.36 | 38.5 | 2 | 58 | 590 x 500 x 860 | 13 |
2 | HL-1500-QG2/2 | 220V, 50Hz | 2.3 | R410A | 0.50 | 47.5 | 2 | 66 | 630 x 510 x 920 | 13 |
3 | HL-2000-QG2/2 | 220V, 50Hz | 2.4 | R410A | 0.65 | 47.5 | 2 | 76 | 650 x 530 x 980 | 20 |
4 | HL-3000-QG2/2 | 220V, 50Hz | 3.1 | R410A | 1.00 | 48.5 | 4 | 93 | 790 x 560 x 1050 | 40 |
5 | HL-4000-QG2/2 | 220V, 50Hz | 5.0 | R410A | 1.20 | 58.5 | 4 | 105 | 850 x 630 x 1225 | 45 |
6 | HL-6000-QG2/2 | 380V, 50Hz | 8.4 | R410A | 1.90 | 58.5 | 4 | 130 | 820 x 700 x 1410 | 60 |
7 | HL-8000-QG2/2 | 380V, 50Hz | 11.0 | R410A | 2.30 | 68.0 | 8 | 200 | 860 x 720 x 1480 | 80 |
8 | HL-12000-QG2/2 | 380V, 50Hz | 14.0 | R410A | 2.70 | 68.0 | 8 | 220 | 1100 x 810 x 1880 | 150 |
9 | HL-15000-QG2/2 | 380V, 50Hz | 15.0 | R410A | 1.8 x 2 | 68.0 | 8 | 310 | 1500 x 800 x 1630 | 180 |
HL-1000 to HL-1500 models are designed for smaller systems with power ranging from 1.7 to 2.3 kW, suitable for cooling lower-power laser machines.
HL-2000 to HL-4000 models offer increased power and cooling capacity, with flow rates of 2 to 4 m³/h, ideal for mid-range laser systems.
HL-6000 to HL-15000 models are designed for heavy-duty laser systems with much higher power requirements, cooling capacities, and flow rates, ensuring efficient operation in more demanding environments.
The HL-12000 High-Power Water Cooling System is designed for optimal cooling of 12000W fiber laser cutting machines, ensuring efficient operation and extending the lifespan of the equipment. Here are the specifications and key features for the HL-12000-QG2/2 model:
Model: HL-12000-QG2/2
Power Supply: 380V, 50Hz
Power Consumption: 14.0 kW
Coolant: R410A
Fluorine Injection: 2.70 kg (amount of refrigerant used)
Lift (Head Pressure): 68.0 meters (capability to pump water to this height)
Flow Rate: 8 m³/h (water flow rate ensuring effective cooling)
Weight: 220 kg (overall weight of the chiller unit)
Equipment Size: 1100 mm * 810 mm * 1880 mm (dimensions of the chiller unit)
Water Volume: 150 liters (capacity of the water tank within the chiller)
High Cooling Capacity: Specifically designed for 12000W fiber laser cutting machines, the HL-12000 provides robust cooling to handle the high thermal load.
Efficient Refrigerant: Uses R410A refrigerant, known for its high efficiency and reduced environmental impact compared to older refrigerants.
Powerful Performance: The chiller’s high power consumption (14.0 kW) indicates its capability to provide effective cooling for high-power laser systems.
Durable Construction: Built to withstand the demands of industrial environments, ensuring long-term reliability and minimal maintenance.
Compact Design: Despite its powerful cooling capabilities, the chiller is designed to fit within a compact footprint, making it suitable for various industrial setups.
Fiber Laser Cutting Machines: Ideal for cooling 12000W fiber laser systems used in industries such as metal fabrication, aerospace, automotive, and other sectors requiring advanced laser cutting technology.
Heavy-Duty Industrial Use: Suitable for environments where continuous, high-performance cooling is required to maintain operational efficiency and equipment longevity.
The HL-12000 ensures that your high-power fiber laser cutting machine operates at optimal temperatures, reducing the risk of overheating and enhancing overall performance. If you need more information or have specific questions about the HL-12000 chiller, feel free to ask!
HL Series Fiber Laser Chillers:
No. | Equipment Model | Power Supply | Power (kW) | Coolants | Fluorine Injection (kg) | Lift (m) | Flow Rate (m³/h) | Weight (kg) | Equipment Size (mm) | Water Volume (L) |
---|---|---|---|---|---|---|---|---|---|---|
1 | HL-1000-QG2/2 | 220V, 50Hz | 1.7 | R410A | 0.36 | 38.5 | 2 | 58 | 590 x 500 x 860 | 13 |
2 | HL-1500-QG2/2 | 220V, 50Hz | 2.3 | R410A | 0.50 | 47.5 | 2 | 66 | 630 x 510 x 920 | 13 |
3 | HL-2000-QG2/2 | 220V, 50Hz | 2.4 | R410A | 0.65 | 47.5 | 2 | 76 | 650 x 530 x 980 | 20 |
4 | HL-3000-QG2/2 | 220V, 50Hz | 3.1 | R410A | 1.00 | 48.5 | 4 | 93 | 790 x 560 x 1050 | 40 |
5 | HL-4000-QG2/2 | 220V, 50Hz | 5.0 | R410A | 1.20 | 58.5 | 4 | 105 | 850 x 630 x 1225 | 45 |
6 | HL-6000-QG2/2 | 380V, 50Hz | 8.4 | R410A | 1.90 | 58.5 | 4 | 130 | 820 x 700 x 1410 | 60 |
7 | HL-8000-QG2/2 | 380V, 50Hz | 11.0 | R410A | 2.30 | 68.0 | 8 | 200 | 860 x 720 x 1480 | 80 |
8 | HL-12000-QG2/2 | 380V, 50Hz | 14.0 | R410A | 2.70 | 68.0 | 8 | 220 | 1100 x 810 x 1880 | 150 |
9 | HL-15000-QG2/2 | 380V, 50Hz | 15.0 | R410A | 1.8 x 2 | 68.0 | 8 | 310 | 1500 x 800 x 1630 | 180 |
HL-1000 to HL-1500 models are designed for smaller systems with power ranging from 1.7 to 2.3 kW, suitable for cooling lower-power laser machines.
HL-2000 to HL-4000 models offer increased power and cooling capacity, with flow rates of 2 to 4 m³/h, ideal for mid-range laser systems.
HL-6000 to HL-15000 models are designed for heavy-duty laser systems with much higher power requirements, cooling capacities, and flow rates, ensuring efficient operation in more demanding environments.
content is empty!