DP GROUP, founded in 2016, offer professional laser solutions and sheet metal fabrication machinery. Headquartered in Hong Kong, we operate three factories in mainland China:
DPMach (Dongguan): Specializes in laser cutting, welding, and marking.
DGDY (Dongguan): Focuses on press brake machines with advanced Panel Bender technology.
DPQG (Foshan): Manufactures large tube laser cutting machines for pipes up to 800mm in diameter and 30 meters lenth.
DP GROUP, founded in 2016, offer professional laser solutions and sheet metal fabrication machinery. Headquartered in Hong Kong, we operate three factories in mainland China:
DPMach (Dongguan): Specializes in laser cutting, welding, and marking.
DGDY (Dongguan): Focuses on press brake machines with advanced Panel Bender technology.
DPQG (Foshan): Manufactures large tube laser cutting machines for pipes up to 800mm in diameter and 30 meters lenth.
Availability: | |
---|---|
Quantity: | |
WF—007A
handheld laser welding machine with wire filling system wire feeding machine
Introduction:
WF-007A Cold filler wire machine (argon arc welding wire feeding machine) is used for argon arc welding, laser welding, plasma welding, brazing welding process, withoutpreheating wire filling equipment for the molten pool.
WF-007A has a total of three kinds of working state, respectively is: the standbystate, parameter setting, running state. Turn on the power switch, which enter the standby state.
Fault diagnosis and treatment table:
serialnumber | The fault phenomenon | The cause of the fault | Corrective measures |
F1 | Boot power indicator light does not shine | 220VPower line fault | Turn off the power immediately, replacement of the input power line
|
220V/24V transformer bad | Replaced the transformer | ||
A power switch lamp bad | Replace the power switch | ||
The power switch is not closed | Switch on | ||
The power switch is bad | Replace the power switch | ||
F2 | Press the start switch to send silk | The main control board is bad | Replacement and main control board |
The starting switch and the motherboard connection broken | Well connected according to the corresponding joint
| ||
The wire feeding motor bad | The replacement of wire feed motor
| ||
Adjusting panel circuit board damaged | Replacement and main control board | ||
Speed control knob in the zero position | Rotation speed control knob | ||
Wire exhausted | the replacement of wire disc | ||
Power no on | Plug the power plug | ||
Wire knot | Release the pressing wheel, the new disc good silk.。 | ||
Wire feeding tube knot | Straighten out the wire feeding tube | ||
wire feeding wheel misalignment | Wire feeding wheel alignment guide tube | ||
Wire feeding tube blockage | Replace wire feeding tube | ||
The pull is not enough | Loosen the wire disc brake | ||
The wire feeding pipe damage | Replace wire feeding tube | ||
F3 | Wire feeding speed instability | Digitalspeed control potentiometer bad | Replace the digital speed control potentiometer |
The main control board is bad | Replacement and main control board | ||
The wire in the wire plate knot | REMOVE the knot section, re winding. | ||
Wire feeding tube does not match or wear | Replace wire feeding tube | ||
Wire feeding wheel is not suitable | Replace wire feeding wheel | ||
pressure wheel pressure is not correct | Adjusted the pressure wheel pressure | ||
Wire relay bad | Replace the relay | ||
F4 | No delay wire | The main control board is bad | Replacement and main control board |
Delay potentiometer and delay selection switch bad | The replacement of delay and delay selection switch potentiometer | ||
Wire relay bad | Replace the relay | ||
F5 | No back spinning | The main control board is bad | Replacement and main control board |
Delay potentiometer and pumping back selection switch is bad | Replace the delay potentiometer and pumping back selection switch | ||
Wire relay bad | The replacement of the time delay relay bad
| ||
Speed control knob bad | Replace the speed control knob | ||
F6 | No pulse feeding | The main control board is bad | Replacement and main control board |
Oscillating wire feeding and selection switch is bad | Replace the oscillating wire feeding and selection switch is bad | ||
Pause time and wire time adjusting knob is bad
| Replacing and adjusting knob potentiometer | ||
F7 | Wire feeding is not smooth | Wire feeding wheel no replacement | The corresponding wire diameter changing wire feeding wheel |
Wire feeding tube plug gambling | Replace or clean the wire feeding tube | ||
The wire feeding pipe twist angle less than 30 degree | Will try to put straight wire feeding tube | ||
Deformation of wire feeding tube extrusion | Replace wire feeding tube | ||
F8 | Wire filling gun out of silk | Wire feeding wheel no compression | Clamping wire feeding wheel |
Wire filling gun catheter and wire feeding hose connected properly | To properly connected wire feeding tube and wire filling gun catheter | ||
Drawing the wire back over | The wire filling gun nozzle unscrew, switch wire resend the point, then the wirethrough the wire filling gun nozzle screw wire filling gun nozzle. | ||
F9 | The wire feeding motor cann’t stop | The power switch is bad | Replace the power switch |
Switch control cable is bad | Replace the switch wire | ||
Power outlet short circuit | Replace the power supply socket | ||
Wire relay bad | Replace the relay | ||
The control circuit board for | Replacement of circuit board | ||
F10 | Other phenomena | Why not check | Processing the return of supplier |
handheld laser welding machine with wire filling system wire feeding machine
Introduction:
WF-007A Cold filler wire machine (argon arc welding wire feeding machine) is used for argon arc welding, laser welding, plasma welding, brazing welding process, withoutpreheating wire filling equipment for the molten pool.
WF-007A has a total of three kinds of working state, respectively is: the standbystate, parameter setting, running state. Turn on the power switch, which enter the standby state.
Fault diagnosis and treatment table:
serialnumber | The fault phenomenon | The cause of the fault | Corrective measures |
F1 | Boot power indicator light does not shine | 220VPower line fault | Turn off the power immediately, replacement of the input power line
|
220V/24V transformer bad | Replaced the transformer | ||
A power switch lamp bad | Replace the power switch | ||
The power switch is not closed | Switch on | ||
The power switch is bad | Replace the power switch | ||
F2 | Press the start switch to send silk | The main control board is bad | Replacement and main control board |
The starting switch and the motherboard connection broken | Well connected according to the corresponding joint
| ||
The wire feeding motor bad | The replacement of wire feed motor
| ||
Adjusting panel circuit board damaged | Replacement and main control board | ||
Speed control knob in the zero position | Rotation speed control knob | ||
Wire exhausted | the replacement of wire disc | ||
Power no on | Plug the power plug | ||
Wire knot | Release the pressing wheel, the new disc good silk.。 | ||
Wire feeding tube knot | Straighten out the wire feeding tube | ||
wire feeding wheel misalignment | Wire feeding wheel alignment guide tube | ||
Wire feeding tube blockage | Replace wire feeding tube | ||
The pull is not enough | Loosen the wire disc brake | ||
The wire feeding pipe damage | Replace wire feeding tube | ||
F3 | Wire feeding speed instability | Digitalspeed control potentiometer bad | Replace the digital speed control potentiometer |
The main control board is bad | Replacement and main control board | ||
The wire in the wire plate knot | REMOVE the knot section, re winding. | ||
Wire feeding tube does not match or wear | Replace wire feeding tube | ||
Wire feeding wheel is not suitable | Replace wire feeding wheel | ||
pressure wheel pressure is not correct | Adjusted the pressure wheel pressure | ||
Wire relay bad | Replace the relay | ||
F4 | No delay wire | The main control board is bad | Replacement and main control board |
Delay potentiometer and delay selection switch bad | The replacement of delay and delay selection switch potentiometer | ||
Wire relay bad | Replace the relay | ||
F5 | No back spinning | The main control board is bad | Replacement and main control board |
Delay potentiometer and pumping back selection switch is bad | Replace the delay potentiometer and pumping back selection switch | ||
Wire relay bad | The replacement of the time delay relay bad
| ||
Speed control knob bad | Replace the speed control knob | ||
F6 | No pulse feeding | The main control board is bad | Replacement and main control board |
Oscillating wire feeding and selection switch is bad | Replace the oscillating wire feeding and selection switch is bad | ||
Pause time and wire time adjusting knob is bad
| Replacing and adjusting knob potentiometer | ||
F7 | Wire feeding is not smooth | Wire feeding wheel no replacement | The corresponding wire diameter changing wire feeding wheel |
Wire feeding tube plug gambling | Replace or clean the wire feeding tube | ||
The wire feeding pipe twist angle less than 30 degree | Will try to put straight wire feeding tube | ||
Deformation of wire feeding tube extrusion | Replace wire feeding tube | ||
F8 | Wire filling gun out of silk | Wire feeding wheel no compression | Clamping wire feeding wheel |
Wire filling gun catheter and wire feeding hose connected properly | To properly connected wire feeding tube and wire filling gun catheter | ||
Drawing the wire back over | The wire filling gun nozzle unscrew, switch wire resend the point, then the wirethrough the wire filling gun nozzle screw wire filling gun nozzle. | ||
F9 | The wire feeding motor cann’t stop | The power switch is bad | Replace the power switch |
Switch control cable is bad | Replace the switch wire | ||
Power outlet short circuit | Replace the power supply socket | ||
Wire relay bad | Replace the relay | ||
The control circuit board for | Replacement of circuit board | ||
F10 | Other phenomena | Why not check | Processing the return of supplier |